Circuit breaker size for 10kw heat strip
WebThe Trane salesperson said according to Trane specs 10 kw is really 9.6 kw and requires 54 amps. I currently have a # 4 aluminum wire up in the attic where this heat strip and air … WebFeb 2, 2024 · To calculate circuit breaker and wire size: Write down an approximation of the total load you will connect to the circuit breaker. Get a circuit breaker rated for …
Circuit breaker size for 10kw heat strip
Did you know?
WebJan 8, 2014 · Wire Size for Air Handler and 10kW heat strip. 13 seer is 10 gauge with 35amp breaker most likely. Air handler is most likely #6 copper and 60 amp breaker. Of … WebHeat Strip Size: 10 kW: Max Overcurrent Protection: 60 amps: Primary Heating Capacity: 30,001 - 35,000 BTU: Product Height (in) 6.5: Product Length (in) 13.25: Product Width …
WebJan 9, 2024 · go with 8kw heat strip or 5 kw heat strip. I live in Tampa, Florida and I just got a new Trane AC system installed in my house. My house is about 2,000 square feet and I got an 4 ton 18 seer system (XV18). The company that installed the system did a great job but it failed the permit inspection. They hooked up an 8kw heat strip … WebNov 3, 2024 · How many amps is a 10kw heat strip? 240volts X 42amps = 10kw so you should be good to go. If your wire is labeled 55amps,55 is the max it should be for but #4 al is normally 65 amp. What size breaker do I need for a 15 kW heater? 15kw is better than 60 Amps. If you are positive that is indeed #4 cable…. you must use a sub panel.
WebApr 12, 2024 · Goodman 15Kw Heat Strip Wiring Diagram. If you go to goodman 2000 cfm electric. ... Goodman 10kw heat strip wiring diagram. Goodman 15Kw Heat Strip Wiring Diagram For Your Needs from mamvic.com The Three Types of Heat Convection, Radiation and Energy Transfer . These forms of energy that are a result of light or heat, are …
WebThis item: Goodman HKR-10C Auxiliary Heat Strip 10Kw with Circuit Breaker $161.97 Goodman 3 Ton 14 Seer Heat Pump System with …
WebMar 3, 2013 · The 10kw heat strip called for a 60amp circuit breaker and I have a 50amp stab-loc breaker in a 200amp Federal Pacific Electric panel from the mid 1960s when the house was built. The tech installed the 10kw for a temporary heat source and came back the next day and installed the 7kw heat strip. tsc tractor supply greenhouseWebJan 19, 2024 · 10 kW Heat Strip Breaker Size. The breaker size for a 10kW heat strip would typically be around 60 amps, as the maximum fuse breaker for this type of device is … phil mchale actorWebThe heat strips are designated 40a per circuit. It's indoors in basement and wire runs from panel are about 25 feet. The heating system was recently installed and HVAC contractor … phil mchugh darwinWebMar 15, 2024 · What size wire is needed for a set of 10kw heat strips? 10KW heat needs a 60 amp breaker and #6 wire. What size circuit and wire is required for a gas furnace? Most furnaces use around 4-6 amps so a 15A circuit has plenty of spare capacity. Your furnace is spec’ing a 15A circuit size. phil mcgraw and wife robinWeb3. For 5kW through 20kW circuit breaker models: Afterinstallingheaterassembly,attachcircuitbreakeras-sembly to unit with screws provided. (See Figure. 3) On fan coil units size 4200 and larger, remove wire tie that shortens wire length between heater and circuit breaker assembly to allow mounting of circuit … tsc tractor supply hastings miWebDec 21, 2024 · A 10kW heater will consume 40A-45A depending on its exact rating. They will add 25% to that for sizing, as its a heater. (the manual will be all inclusive, so it's better to use the numbers from the manufacturer.) The calculators say between awg 6 - 10 for 50ft, depending on conditions. (1-3% voltage drop respectfully.) tsc tractor supply hollister moWeb240volts X 42amps = 10kw so you should be good to go. If your wire is labeled 55amps,55 is the max it should be for but #4 al is normally 65 amp. lin51 Original Author 8 years ago … tsc tractor supply hazen nd